Dc to ac converter Field of use:
In vehicle system: Provides stable energy storage power for vehicle electronic devices, suitable for various
in vehicle charging and inverter.
Commercial use: Suitable for maintaining power in various electronic devices in commercial environments,
such as cash registers, lighting, etc.
Industrial application: Provide reliable uninterrupted power supply for industrial equipment, ensuring the
continuity of production power supply.
Civil equipment: Home energy storage backup, commonly used appliances such as air conditioners, televisions,
and refrigerators can all be powered by this inverter power supply.
Telecommunications and electricity: providing uninterrupted power supply for key equipment such as
Telecommunications base stations and power monitoring.
Dc to ac converter Main uses
Household appliances: air conditioning, television, refrigerator, washing machine, etc.
Office equipment: computers, printers, copiers, etc.
Commercial equipment: cash registers, POS machines, advertising display screens, etc.
Electric tools: various electric tools and mechanical equipment.
Lighting system: indoor and outdoor lighting equipment.
Industrial equipment: production lines, mechanical equipment, etc.
Telecommunications equipment: communication base stations, network equipment, etc.
EVSPOWER DC220V Series | ||||||||||
rated power | 1KW | 2KW | 3KW | 4KW | 5KW | 6KW | 8KW | 10KW | 12KW | |
Rated DC voltage | DC216V | |||||||||
Battery voltage range |
DC180-288V | Low voltage warning | 198V | |||||||
Low voltage power outage | 189V(180-216V(ADJ) | |||||||||
Low voltage recovery | 243V | |||||||||
High voltage power outage | 283.5V(274.5-288V ADJ) | |||||||||
High voltage recovery | 279V | |||||||||
Low voltage shutdown | 171Vdc | |||||||||
DC priority type | Low voltage switching of battery to mains voltage point | 198V(189-229.5V) | ||||||||
Return to the battery supply voltage point after sufficient supply | 234V(216-261V) |
Communication input | Rated AC input voltage | AC220V | AC110V | ||||||||||
Scope of communication input | 170-280Vac(UPS) 90-280Vac(APL) | ||||||||||||
Voltage drop point due to under voltage of the municipal power supply | 170Vac±5V (UPS) 90Vac±5V (APL) | ||||||||||||
Under voltage recovery point of municipal power supply | 180Vac±5V (UPS) 100Vac±5V (APL) | ||||||||||||
Overvoltage and power failure voltage point of mains power | 280Vac±5V | ||||||||||||
Overvoltage recovery voltage point of mains power | 270Vac±5V | ||||||||||||
Communication input frequency | 50HZ/60HZ(ADJ) | ||||||||||||
Frequency range | 40-65HZ | ||||||||||||
Single mains power on function | yes | ||||||||||||
UPS conversion time | <5ms(UPS);<13ms(Electrical mode) | ||||||||||||
AC output | AC output voltage | 220/230/240Vac±3% ADJ | |||||||||||
Communication output frequency | 50±1HZ/60±1HZ | ||||||||||||
Output waveform | Pure sine wave (full voltage range) | ||||||||||||
Waveform distortion rate | ≤3%(Linear Load) | ||||||||||||
Inverter peak efficiency | 95% | ||||||||||||
Dynamic response | (0~100%)≤5% | ||||||||||||
Power factor | >0.9 | ||||||||||||
Peak power (surge capability) | Twice the rated power in 3 seconds | ||||||||||||
Idle power consumption (standby power consumption) | 30W | ||||||||||||
power derating | No derating (output power will not decrease with the decrease of battery voltage) | ||||||||||||
work environment | Noise (1 meter) | ≤40dB | |||||||||||
Environmental temperature for use | -40℃~+50℃ | ||||||||||||
Storage environment temperature | -40℃~+70℃ | ||||||||||||
humidity | 0~90% | ||||||||||||
Using altitude (m) | ≤ 5000 (If it is higher than 1000, the usage will be reduced by 10% per liter starting from 1000) | ||||||||||||
Continuous running time | Can run continuously for a long time | ||||||||||||
Cooling method | Temperature controlled variable speed fan for heat dissipation | ||||||||||||
Mean time between failures | Not less than 100000 hours |